CLOSING CHECK/EXTEND
Opening and Closing Schedules may be utilized to check to see
if the burglary system is armed by a scheduled time each day. The
closing check feature will verify that all areas of the system are
armed when the permanent and temporary schedule expires. If an
area is not armed the keypad will display CLOSING TIME.* The
steady trouble tone will also sound. If the system is not armed or a
schedule extended within ten minutes, a no closing report will be
transmitted to the central station receiver.
The closing schedule can be lengthened by entering a temporary
schedule or using the extend feature. The extend function step by
step follows. Temporary schedules are described in the schedule
menu option section.
If an area has been disarmed outside of any permanent or tempo-
rary schedule, the closing check sequence will occur one hour after
the area was disarmed.
Extending A Schedule is accomplished by pressing a top row key
to silence the closing time display. After a valid code number is
accepted the keypad will request the new closing time. Any time
may be entered up to 11:59 p.m. If no time is entered the closing
time will be extended for one hour.
Step by Step:
1. When a schedule expires CLOSING TIME! *
will be displayed and the steady trouble
tone will sound.
2. Press any top row key to silence the tone. The display will read
ENTER CODE:- .
3. Enter at least a level six code number and press
.
The display will read - : AM PM .
AM PM
4. Enter the new closing time and press the or
key.
5. If no time is entered in step 4, the schedule will be extended for
one hour
* If the system has been programmed to provide independent
schedules per
area, the closing time will be replaced by AREA NAME-LATE
.
COMMAND
6
14
FIRE RESET
detectors are automatically reset. Insure that all smoke is cleared
from the detector before resetting.
Step By Step:
1. Press the key until FIRE RESET? is
displayed.
2. When FIRE RESET? is displayed press any one of
the top four
select keys. The display will read ENTER CODE:- .
User Code Level: 1- During permanent or temporary
schedules only
3- Anytime
Function: Resets smoke detectors
Fire Reset is used to reset smoke detectors after they have been
tripped. Once a smoke detector has been tripped it must be reset
before it will function again. When Fire Reset is selected the smoke
COMMAND
COMMAND