SPEC SHEET
OUTPUTS
The XR500 allows the use of two SPDT relay
outputs with a 431 Output Harness, and four
open collector outputs using a Model 300
Output Harness. Multiple outputs can be
grouped to activate with a single event.
Output Groups can be assigned to a particular
user profile. Up to 500 outputs may be used
on the XR500 LX-Bus with 716 Output Modules.
SCHEDULES
The XR500 provides system operation
flexibility using a variety of programmable
schedules as described below. There are 100
total schedules available for use.
OUTPUT SCHEDULES
Output (relay) schedules automatically turn any
of the systems relays or switched-ground outputs
on or off. This feature allows control of exterior
lighting or any contact-activated device.
With a Model 739 X-10 Interface Module on
the LX-Bus users can program schedules for
their X-10 devices. This allows the panel
LX-Bus outputs to control the X-10 device
on/off status. The 739 module does not
require any address programming.
HOLIDAY DATES AND
SCHEDULES
The XR500 allows up to 20 different user
selectable holiday dates that override the
normal schedules. Independent holiday
schedules are available for each of the 32
burglary areas, system relay output operation,
and door strike operation. All holiday dates
can be assigned up to one year in advance.
SHIFT SCHEDULES
Each system area can have a shift schedule.
Each user access card can be assigned to operate
during one or more of the four shift schedules,
or allowed to operate regardless of any
schedule. This schedule is also used by the
burglary system to determine if a particular
area is not armed by the scheduled closing time.
DOOR STRIKE SCHEDULES
WITH OVERRIDE
Door strike schedules are also provided to allow
door strike control. Specific doors may be set
to unlock certain times of the day or night, or
the card reader can be completely disabled
when desired. The schedule override feature
keeps doors locked should the business open
late or close early due to inclement weather
or other emergency.
AUTOMATIC BURGLARY
SYSTEM DISARMING
Since the XR500 is an integrated burglary, fire,
and access control system, a user can gain
access and disarm the site, all in a single card
read!
SECURITY COMMAND
®
KEYPAD
You can connect any LCD Security Command
keypad to the XR500 system. Each keypad
has large function keys for entering
information and a backlit LCD display that
allows users to view system events in almost
all lighting conditions.
EASY ENTRY™ KEYPADS
For low cost access control, DMP offers Easy
Entry™ keypads with a built-in proximity
reader. You can also connect external
proximity and magnetic stripe access readers
to some Easy Entry keypad models.
The keypad Soft Shunt™ feature shunts a zone
on the keypad while the user enters or leaves
the building.
Using a Model 733 or 734 Wiegand Interface
Module a door strike relay or magnetic lock
can allow users to exit an area without
presenting a card.
16 INDEPENDENT DOORS OF
ACCESS CONTROL
Any access control reader that provides a 26-
40 bit Wiegand output can be connected to
the XR500 using the Model 733 or 734
Wiegand Interface Modules, or Easy Entry™
keypads. Attach card reader inputs from up
to 16 different locations.
FOUR PROGRAMMABLE
ENTRY DELAY TIMES
Delay zones on the XR500 can be assigned to
any of the four programmable entry delays.
Program entry times for 1 to 250 seconds.
ANTI-PASSBACK
The XR500 offers anti-passback operation.
Specific doors and readers can be designated
for access to, or egress from, particular areas
in the system.
ACCESS DENIED REPORTS
The XR500 system can restrict access for
several reasons such as a schedule or armed
area. The specific reason for access denial
can be displayed on the keypad, stored in
events, logged on a local printer (DMP 462P
required), sent to the central station, or to
DMP Advanced Reporting software.
12,000 EVENT MEMORY
The XR500 stores up to 12,000 events. The
10,000 Display Events feature allows you to
view stored openings and closings, zone
events, user code and schedule changes, door
accesses, and supervisory events. Sort events
by a particular user, door, and date range.
The remaining 2,000 events list alarm events
separately for easy review and research.
EVENTS MANAGER
Save monitoring costs with the XR500 by using
the Events Manager option. This feature
allows the panel to buffer specific system
reports and automatically download them to
the receiver when the available memory is
full or keep them in memory until downloaded
with DMP Remote Link™ Software.
FIRE DRILL AND ONE-MAN
WALK TEST
Users can test fire notification bells using the
Fire Drill feature. A special code is also
available for installers to test the system.
The one-man walk test feature allows a single
technician to check the panel response to
burglary, fire, panic and supervisory zones.
The trip counter and failed zones display
provide a printable report.
XR500N NETWORK VERSION
The XR500N Network version is the perfect
solution for multi-site applications where the
Internet or LAN/WAN is available.
The XR500N provides built-in Ethernet network
communication featuring enhanced network
options that provide customizable check-in
times and retry times. TCP communications
is also an available option.
In addition, the XR500N provides greater
security for banks with Bank Safe & Vault
operation, Two-Man Rule, Panic Button Test,
and Early Morning Ambush features.
XR500E ENCRYPTED
VERSION
In addition to all the XR500N capabilities the
XR500E offers AES (Advanced Encryption
Standard) Rijndael Encryption. The XR500E
does not require a separate router to provide
encrypted data transmission.
Using a unique alphanumeric Passphrase the
XR500E ensures encrypted data transmits
securely and safely. Ideal for secure
environments where encrypted data is
required.
UL Listed and NIST Certified Encryption. See
www.nist.com
Easy-to-read English Display
Large, backlit function keys
Built-in
speaker
Power LED
Armed LED
Commenti su questo manuale