Printer Trouble
Is the panel connected to a printer?
YES - [ PRINTER -TRBL ] means that the 462P card isn’t getting the Clear to Send (CTS)
voltage.
Check RJ-cable between 462P and printer. Should see 5 to 15 VDC for CTS
(Clear to Send) voltage between the cable's pins 6 and 7 at the 462P end.
Check dip-switch settings on printer. (See next page.)
Model 462P Printer Card
NO - [ PRINTER -TRBL ] means that one or more options in Printer Reports is set to YES.
TECH NOTE: While the 462P Printer Interface Card will work with other serial printers, DMP
Technical Services only provide technical support for Okidata Microline 184T printers.